{"id":694,"date":"2016-07-11T10:30:53","date_gmt":"2016-07-11T08:30:53","guid":{"rendered":"http:\/\/www.aerre2.com\/en\/?page_id=694"},"modified":"2021-04-14T14:22:53","modified_gmt":"2021-04-14T12:22:53","slug":"pressure-transducer","status":"publish","type":"page","link":"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/","title":{"rendered":"Pressure transducer"},"content":{"rendered":"<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 hundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"background-color: rgba(255,255,255,0);background-position: center center;background-repeat: no-repeat;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;margin-bottom: 0px;margin-top: 0px;border-width: 0px 0px 0px 0px;border-color:#eae9e9;border-style:solid;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"margin-top:0px;margin-bottom:20px;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\" style=\"background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;padding: 0px 0px 0px 0px;\"><style type=\"text\/css\"><\/style><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"margin-top:0px;margin-right:0px;margin-bottom:31px;margin-left:0px;\"><h2 class=\"title-heading-left\" style=\"margin:0;\">Pressure transducer type tp1 for one control panel type 1QM\/CE 1QT\/CE, Q2PM\/CE, Q2PT\/CE and Q3PM\/CE Q3PT\/CE.<\/h2><\/div><div class=\"fusion-text fusion-text-1\"><p>The pressure transducer type TP1 is a sensor suitable to be fixed in the tube outlet\u00a0of our collectors in steel AISI 304.<\/p>\n<\/div><div class=\"fusion-text fusion-text-2\"><p>It has the ability to read something as strong\u00a0as pressure and transform it through an electric circuit in a voltage of between 0V\u00a0up to 5V.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_2_5 2_5 fusion-two-fifth fusion-column-first\" style=\"width:37.6%; margin-right: 4%;margin-top:0px;margin-bottom:20px;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\" style=\"background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;padding: 0px 0px 0px 0px;\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img alt=\"aerre2 pressure transducer\" src=\"http:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-pressure-transducer.jpg\" class=\"img-responsive\"\/><\/span><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_3_5 3_5 fusion-three-fifth fusion-column-last\" style=\"width:58.4%;margin-top:0px;margin-bottom:20px;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\" style=\"background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;padding: 0px 0px 0px 0px;\"><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"margin-left: auto;margin-right: auto;margin-top:20px;width:100%;\"><\/div><div class=\"fusion-sep-clear\"><\/div><style type=\"text\/css\"><\/style><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"margin-top:0px;margin-right:0px;margin-bottom:5px;margin-left:0px;\"><h2 class=\"title-heading-left\" style=\"margin:0;\">MANIPULATION OF THE LEVEL TRANSDUCERS TYPE TDL1<\/h2><\/div><ul class=\"fusion-checklist fusion-checklist-1\" style=\"font-size:13px;line-height:22.1px;\"><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Move the level transducer with great care, as is it a very<strong> sensitive product and can be easily damaged by being\u00a0knocked or shaken.<\/strong><\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\"><strong>Fix the level transducer in the sleeve by screwing in. Take care not to create any pressure, so ensure that the\u00a0shutter is open. An extra pressure of one bar for the 200cm type irreparably damages the transducer with\u00a0the subsequent breaking of the membrane<\/strong><\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Each time that the tank is completely emptied, that is below 10 cm, after re-filling it is important to release the air\u00a0from the transducer through opening the screw. This is only to be carried out on surface transducers.<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Do not enter the hole of the transducer with a pointed object and press on the membrane or apply pressure on it.<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Pressure over one bar will irreparably damage the transducer.<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Keep away from direct heat<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Keep away from radio equipment<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Do not bend the electric cable into a \u201cU\u201d shape<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Fix the connector from the transducer to electric card, with the cable facing down. The connector is polarised, but\u00a0in any case the incorrect assembly of the connector irreparably damages the transducer.<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Do not unscrew the socket-head screw. Opening these causes the transducer to work incorrectly.<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Ensure that the transducer is fixed at a height of 10cm from the release air screw at the bottom of the tank. Failure\u00a0to observe this level will causes an incorrect reading of the liquid level.<\/div><\/li><\/ul><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"margin-left: auto;margin-right: auto;margin-top:25px;width:100%;\"><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-button-wrapper\"><style type=\"text\/css\">.fusion-button.button-1 {border-radius:2px;}<\/style><a class=\"fusion-button button-flat fusion-button-default-size button-default button-1 fusion-button-default-span bottone-blu\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"http:\/\/www.aerre2.com\/eng\/prodotti\/scheda_trasduttore_di_pressione.pdf\"><span class=\"fusion-button-icon-divider button-icon-divider-left\"><i class=\" fa fa-file-pdf-o\" aria-hidden=\"true\"><\/i><\/span><span class=\"fusion-button-text fusion-button-text-left\">Download data sheet<\/span><\/a><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"margin-top:0px;margin-bottom:20px;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\" style=\"background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;padding: 0px 0px 0px 0px;\"><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"margin-left: auto;margin-right: auto;margin-top:30px;margin-bottom:30px;width:100%;\"><div class=\"fusion-separator-border sep-single sep-solid\" style=\"border-color:#e0dede;border-top-width:1px;\"><\/div><\/div><div class=\"fusion-sep-clear\"><\/div><style type=\"text\/css\"><\/style><div class=\"fusion-title title fusion-title-3 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"margin-top:0px;margin-right:0px;margin-bottom:5px;margin-left:0px;\"><h2 class=\"title-heading-left\" style=\"margin:0;\">MANIPULATION OF THE LEVEL TRANSDUCER YPE TPL1<\/h2><\/div><ul class=\"fusion-checklist fusion-checklist-2\" style=\"font-size:13px;line-height:22.1px;\"><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Do not enter the hole of the transducer with a pointed object and press on the membrane or apply pressure on it.\u00a0Pressure over 25 bars will irreparably damage the transducer.<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Keep away from direct heat<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Keep away from radio equipment<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Do not unscrew the transducer. The opening of this causes damage to the pressure transducer.<\/div><\/li><li class=\"fusion-li-item\"><span style=\"height:22.1px;width:22.1px;margin-right:9.1px;\" class=\"icon-wrapper circle-no\"><i class=\"fusion-li-icon fa fa-chevron-right\" style=\"color:#f15026;\" aria-hidden=\"true\"><\/i><\/span><div class=\"fusion-li-item-content\" style=\"margin-left:31.2px;\">Do not bend the electric cable into a \u201cU\u201d shape<\/div><\/li><\/ul><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"margin-left: auto;margin-right: auto;margin-top:25px;width:100%;\"><\/div><div class=\"fusion-sep-clear\"><\/div><style type=\"text\/css\"><\/style><div class=\"fusion-title title fusion-title-4 fusion-sep-none fusion-title-text fusion-title-size-two\" style=\"margin-top:0px;margin-right:0px;margin-bottom:5px;margin-left:0px;\"><h2 class=\"title-heading-left\" style=\"margin:0;\"><\/h2><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator fusion-full-width-sep\" style=\"margin-left: auto;margin-right: auto;margin-top:20px;width:100%;\"><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-text fusion-text-3\"><table class=\"tg\">\n<tbody>\n<tr class=\"tr-grigio\">\n<th class=\"tg-yw4l\"><strong>TRANSDUCER TYPE<\/strong><\/th>\n<th class=\"tg-yw4l\"><strong>TP1\/10 BAR<\/strong><\/th>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">TENSION FEED<\/td>\n<td class=\"tg-yw4l\">+5V Stabilizing<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">TENSION OUTPUT<\/td>\n<td class=\"tg-yw4l\">0V &#8211; +5V<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">LINEARITY<\/td>\n<td class=\"tg-yw4l\">\u00b10,4%<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">STABILITY<\/td>\n<td class=\"tg-yw4l\">0,5% max.<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">TYPICAL TOTAL MARGIN ERROR<\/td>\n<td class=\"tg-yw4l\">\u00b1 2,0%<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">WORKING LIFE OF TRANSDUCER<\/td>\n<td class=\"tg-yw4l\">-20\u00b0C + 50\u00b0C<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">STABILITY<\/td>\n<td class=\"tg-yw4l\">0,25% max<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">TYPICAL TOTAL MARGIN OF ERROR<\/td>\n<td class=\"tg-yw4l\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">TYPICAL TOTAL MARGIN OF ERROR<\/td>\n<td class=\"tg-yw4l\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">WORKING LIFE OF THE TRANSDUCER<\/td>\n<td class=\"tg-yw4l\">1 Milion full loads<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">WORKING PRESSURE<\/td>\n<td class=\"tg-yw4l\">10bar<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">OVERPRESSURE<\/td>\n<td class=\"tg-yw4l\">25 bar max.<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">WORKING TEMPERATURE<\/td>\n<td class=\"tg-yw4l\">-20\u00b0C+40\u00b0C<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">CONNECTION<\/td>\n<td class=\"tg-yw4l\">1\/4\u201dG<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">ASSEMBLY<\/td>\n<td class=\"tg-yw4l\">Vertical\/Horizontal<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">SENSOR MATERIAL<\/td>\n<td class=\"tg-yw4l\">CERAMICS<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">TRANSDUCER MATERIAL<\/td>\n<td class=\"tg-yw4l\">BRASS<\/td>\n<\/tr>\n<tr>\n<td class=\"tg-yw4l\">\u00d8 TRANSDUCER<\/td>\n<td class=\"tg-yw4l\">32 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><style type=\"text\/css\">.fusion-fullwidth.fusion-builder-row-1 { overflow:visible; }<\/style><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":52,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v18.4.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Pressure transducer | Aerre2<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pressure transducer | Aerre2\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/\" \/>\n<meta property=\"og:site_name\" content=\"Aerre2\" \/>\n<meta property=\"article:modified_time\" content=\"2021-04-14T12:22:53+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-pressure-transducer.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.aerre2.com\/it\/#organization\",\"name\":\"Aerre2\",\"url\":\"https:\/\/www.aerre2.com\/it\/\",\"sameAs\":[],\"logo\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.aerre2.com\/it\/#logo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-logo-sticky.jpg\",\"contentUrl\":\"https:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-logo-sticky.jpg\",\"width\":150,\"height\":74,\"caption\":\"Aerre2\"},\"image\":{\"@id\":\"https:\/\/www.aerre2.com\/it\/#logo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.aerre2.com\/it\/#website\",\"url\":\"https:\/\/www.aerre2.com\/it\/\",\"name\":\"Aerre2\",\"description\":\"controlli di livello dei liquidi per qualsiasi applicazione\",\"publisher\":{\"@id\":\"https:\/\/www.aerre2.com\/it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.aerre2.com\/it\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"http:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-pressure-transducer.jpg\",\"contentUrl\":\"http:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-pressure-transducer.jpg\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/#webpage\",\"url\":\"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/\",\"name\":\"Pressure transducer | Aerre2\",\"isPartOf\":{\"@id\":\"https:\/\/www.aerre2.com\/it\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/#primaryimage\"},\"datePublished\":\"2016-07-11T08:30:53+00:00\",\"dateModified\":\"2021-04-14T12:22:53+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.aerre2.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.aerre2.com\/en\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Accessories for electric panel\",\"item\":\"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Pressure transducer\"}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Pressure transducer | Aerre2","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/","og_locale":"en_US","og_type":"article","og_title":"Pressure transducer | Aerre2","og_url":"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/","og_site_name":"Aerre2","article_modified_time":"2021-04-14T12:22:53+00:00","og_image":[{"url":"http:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-pressure-transducer.jpg"}],"twitter_card":"summary","twitter_misc":{"Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Organization","@id":"https:\/\/www.aerre2.com\/it\/#organization","name":"Aerre2","url":"https:\/\/www.aerre2.com\/it\/","sameAs":[],"logo":{"@type":"ImageObject","@id":"https:\/\/www.aerre2.com\/it\/#logo","inLanguage":"en-US","url":"https:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-logo-sticky.jpg","contentUrl":"https:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-logo-sticky.jpg","width":150,"height":74,"caption":"Aerre2"},"image":{"@id":"https:\/\/www.aerre2.com\/it\/#logo"}},{"@type":"WebSite","@id":"https:\/\/www.aerre2.com\/it\/#website","url":"https:\/\/www.aerre2.com\/it\/","name":"Aerre2","description":"controlli di livello dei liquidi per qualsiasi applicazione","publisher":{"@id":"https:\/\/www.aerre2.com\/it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aerre2.com\/it\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"ImageObject","@id":"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/#primaryimage","inLanguage":"en-US","url":"http:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-pressure-transducer.jpg","contentUrl":"http:\/\/www.aerre2.com\/wp-content\/uploads\/2016\/07\/aerre2-pressure-transducer.jpg"},{"@type":"WebPage","@id":"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/#webpage","url":"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/","name":"Pressure transducer | Aerre2","isPartOf":{"@id":"https:\/\/www.aerre2.com\/it\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/#primaryimage"},"datePublished":"2016-07-11T08:30:53+00:00","dateModified":"2021-04-14T12:22:53+00:00","breadcrumb":{"@id":"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/pressure-transducer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aerre2.com\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.aerre2.com\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Accessories for electric panel","item":"https:\/\/www.aerre2.com\/en\/products\/accessories-for-electric-panel\/"},{"@type":"ListItem","position":4,"name":"Pressure transducer"}]}]}},"_links":{"self":[{"href":"https:\/\/www.aerre2.com\/en\/wp-json\/wp\/v2\/pages\/694"}],"collection":[{"href":"https:\/\/www.aerre2.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.aerre2.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.aerre2.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aerre2.com\/en\/wp-json\/wp\/v2\/comments?post=694"}],"version-history":[{"count":9,"href":"https:\/\/www.aerre2.com\/en\/wp-json\/wp\/v2\/pages\/694\/revisions"}],"predecessor-version":[{"id":1544,"href":"https:\/\/www.aerre2.com\/en\/wp-json\/wp\/v2\/pages\/694\/revisions\/1544"}],"up":[{"embeddable":true,"href":"https:\/\/www.aerre2.com\/en\/wp-json\/wp\/v2\/pages\/52"}],"wp:attachment":[{"href":"https:\/\/www.aerre2.com\/en\/wp-json\/wp\/v2\/media?parent=694"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}